beautypg.com

Status commands, System commands – AMETEK ReFlex Programming Manual User Manual

Page 133

background image

Fixed Power DC Remote Programming

ReFlex Power™ Programming Manual

M380056-03 Rev L

129

6.7

STATUS COMMANDS

6.7.1

STATUS

SCPI

C

OMMAND

S

UMMARY

STATus

:MODule

:ENABles <0+NR1>

:ENABles?

:FAULts?

:HWREV?

6.7.2

STATUS

SCPI

C

OMMAND

R

EFERENCE

Command

Description

STATus

STATUS subsystem of commands..

:MODule

:ENABles<0+NR1>

Enable supervisory faults, see Table

6-2

. Same

Table describes Fault bits.

:ENABles?

Query the enabled supervisories

:FAULts?

Query the supervisory faults.

:HWREV?

Returns Module type and Hardware Revision

Table 6-2. Fixed Power Faults and Enable Register

Bit

Hex Value

Mnemonics

Description

0

0x00000001

P5VF

Plus 5 Volt Fault

1

0x00000002

M5VF

Minus 5 Volt Fault

2

0x00000004

P15VF

Plus 15 Volt Fault

3

0x00000008

M15VF

Minus 15 Volts Fault

4

0x00000010

OTP

Over Temperature Fault

5

0x00000020

5VSNSF

5 Volt House Keeping Sense Fault

6

0x00000040

12VSNSF

12 Volt House Keeping Sense Fault

7

0x00000080

PWROKF

Power Ok Fault

6.8

SYSTEM COMMANDS

6.8.1

SYSTEM

SCPI

C

OMMAND

S

UMMARY

SYSTem

:ERRor?

6.8.2

SYSTEM

SCPI

C

OMMAND

R

EFERENCE

Command

Description

SYSTem

SYSTEM subsystem of commands.

:ERRor?

Returns the last error logged in the Error/Event Queue. The message,
“0, No error”, is returned if there are no errors.