Status commands, System commands – AMETEK ReFlex Programming Manual User Manual
Page 133
Fixed Power DC Remote Programming
ReFlex Power™ Programming Manual
M380056-03 Rev L
129
6.7
STATUS COMMANDS
6.7.1
STATUS
SCPI
C
OMMAND
S
UMMARY
STATus
:MODule
:ENABles <0+NR1>
:ENABles?
:FAULts?
:HWREV?
6.7.2
STATUS
SCPI
C
OMMAND
R
EFERENCE
Command
Description
STATus
STATUS subsystem of commands..
:MODule
:ENABles<0+NR1>
Enable supervisory faults, see Table
6-2
. Same
Table describes Fault bits.
:ENABles?
Query the enabled supervisories
:FAULts?
Query the supervisory faults.
:HWREV?
Returns Module type and Hardware Revision
Table 6-2. Fixed Power Faults and Enable Register
Bit
Hex Value
Mnemonics
Description
0
0x00000001
P5VF
Plus 5 Volt Fault
1
0x00000002
M5VF
Minus 5 Volt Fault
2
0x00000004
P15VF
Plus 15 Volt Fault
3
0x00000008
M15VF
Minus 15 Volts Fault
4
0x00000010
OTP
Over Temperature Fault
5
0x00000020
5VSNSF
5 Volt House Keeping Sense Fault
6
0x00000040
12VSNSF
12 Volt House Keeping Sense Fault
7
0x00000080
PWROKF
Power Ok Fault
6.8
SYSTEM COMMANDS
6.8.1
SYSTEM
SCPI
C
OMMAND
S
UMMARY
SYSTem
:ERRor?
6.8.2
SYSTEM
SCPI
C
OMMAND
R
EFERENCE
Command
Description
SYSTem
SYSTEM subsystem of commands.
:ERRor?
Returns the last error logged in the Error/Event Queue. The message,
“0, No error”, is returned if there are no errors.