AMETEK ReFlex Programming Manual User Manual
Page 52
ReFlex Power™ Programming Manual
Controller Module Remote Programming
48
M380056-03 Rev M
Error Queue not Empty
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
&
&
&
&
&
&
&
&
7 6 5 4 3 2 1 0
&
&
&
&
&
&
&
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
&
&
&
&
&
&
&
&
STAT
STAT
STAT
*STB?
*SRE
*SRE?
*ESE
*ESE ?
*ESR?
SRQ
Error
Queue
6 Service ReQuested
5 Standard Event Status register
4,2 Error Event Queue / Message Available
1 Protection Event Flag
0,3,6,7 Reserved
7 Modules Power On Reset
5 Command Syntax error
4 Command execution error
3 Other errors
0 *RST required after a cold start
1,2,6 Reserved
Sticky bits, cleared on Query
='s 1, if any bit is set
& = 'and' function
KEY:
7 ---- 5 4 3 2 1 0
Ver 0.10
Protection Event Register
Protection Event Enable Register
Enable Standard Event register
standard Event Status Register
ST
atus
B
yte
Service Request Enable / STatus Byte register bits
SYST:MODSRQ?
Returns a 96 bit hexnumber, with
a '1' bit set for each module
requesting an SRQ (96..1)
STAT
Returns a non-sticky version
of the PROT:EVENT Register
3 Output Voltage Fault
2 Summary bit
1 Constant Current Operation
0 Constant Voltage Operation
7 Over Current Fault
6 Volt|Curr Mode Fault
5 Module Disabled
4 Over Temperature Fault
1
2
2
Note 1: Any changes in bits 7-3, 1-0 will set this bit.
Note 2: Short duration mode changes of < 50 mSec. may
not be detected. For the Load Module: Bit 0 is for
Resistance mode operation.
SYST:FAUL?
Returns a 96 bit hex number, with
a '1' bit set for each module with
non-zero fault register (96..1)