ReFlex Power™ Programming Manual

DC Module Remote Programming

72

M380056-03 Rev M

Figure 3-6 and Table 3-6 specify the trigger out signals.

Figure 3-6. Output Trigger Timing

Table 3-6. Output Trigger Specifications

Trigger

Range

2

(Volts)

Low Level

3

(Volts)

High Level

(Volts)

Timing

(Microseconds)

Output Voltage and Current

1

+5.5 V to –0.7V

Vol <= 0.3V @
1mA

Voh >= 4.13
@ 1mA

Trigger Latency

4

Tlout

5

Positive Assertion Period

Touth

2

Negative Assertion Period

Toutl

2

Trigger Recovery Time

Trt > Toutx + 4

1

Typical high-level leakage current is 0.01 mA @ 5.5V DC.

2

All voltages are with respect to the associated return signal.

3

Maximum low-level sink current is 7 mA.