Fixed Power DC Remote Programming

ReFlex Power™ Programming Manual

M380056-03 Rev L

127

6.5.2

CALIBRATION

SCPI

C

OMMAND

R

EFERENCE

Command

Description

CALibrate

1

CALIBRATE sub-commands

:UNLock

Enables the EEPROM memory for storing calibration constants.
The enable string is <“6867”>.

:STORe

Stores the calibration constants in the EEPROM memory.

:LOCK

Disables access to the EEPROM memory, thereby preventing
storing of calibration constants.

:POSitive15 <0+NR1>

Calibration for Positive 15 DC supply. Value is between 0 to 255

:POSitive15?

Query the pot setting

:POSitive5 <0+NR1>

Calibration for Positive 5 DC supply. Value is between 0 to 255

:POSitive5?

Query the pot setting

:NEGative15 <0+NR1>

Calibration for Negative 15 DC supply. Value is between 0 to 255

:NEGative15?

Query the pot setting

:NEGative5 <0+NR1>

Calibration for Negative 5 DC supply. Value is between 0 to 255

:NEGative5?

Query the pot setting

:MODule

:LASTCAL

Set the last calibration date

:LASTCAL?

Query the last calibration date

:NEXTCAL

Set the next calibration date

:NEXTCAL?

Query the next calibration date.

1

Calibration is required to be run twice, once with Sense relays closed and with Sense

relays open, then Store the calibration constants.