ReFlex Power™ Programming Manual

AC Module Remote Programming

100

M380056-03 Rev L

4.8

OUTPUT SCPI COMMANDS

4.8.1

OUTPUT

SCPI

C

OMMAND

S

UMMARY

OUTPut

:STATe

:STATe?

:AUXRelay

:AUXRelay?

:ISOlation?

:SENSe?


4.8.2

OUTPUT

SCPI

C

OMMAND

R

EFERENCE

Command

Description

OUTPut

OUTPUT subset of SCPI commands.

:STATe

Sets the output On or Off. Arguments are 1/ON, or 0/OFF.

:STATe?

Returns the state of the supply, 1 = On, and 0 = Off.

:AUXRelay

Set the Auxiliary Relay to open or close. 1= close ,and 0 = open.
Note: AUX Relay can be manipulated only when the output is On, and
output signal frequency is set within 350 - 1000 Hz range.

:AUXRelay?

Query the state of the Auxiliary relay

:ISOLation?

Query the state of the Isolation relay.

:SENSe?

Query the state of the Sense relay.