ReFlex Power™ Programming Manual

M380056-03 Rev L

33

2.6

LAUNCHING CONTROL COMMUNICATION

When the Ethernet interface is up and running, then start the communication
program as follows:

1. Copy the EnetTest.exe file supplied on the ReFlex Power™ CD-ROM into

any convenient directory on the control computer.

2. In its new location double-click the EnetTest.exe file.

This brings up the Elgar Net Test window (Figure 2-13) where the Host IP
and Port addresses must be set before control communication can begin.

Figure 2-13. Net Test Window

In the Host and Port fields of the Net Test window:

3. Enter the Host IP address acquired by the LXI™ Discovery Browser (Section

2.4.3), or the static IP address that you entered in the Ethernet Configuration
page (AutoIP will be in the range of 169.254.[1 thru 254].[0 thru 255].

4. Set the Port address to: 2340 (required)

5. Click the Connect button.