DC Module Remote Programming

ReFlex Power™ Programming Manual

M380056-03 Rev L

71

down to about 1.3 V where upon the next trigger is asserted. This is termed
de-assertion for differentiation but in fact it is just the next trigger event.

Figure 3-5. Trigger Signal Types

Table 3-5 provides the detailed input trigger signal specifications for the
various states.

Table 3-5. Input Trigger Signal Specifications

Trigger

Range

2

(Volts)

Low Level

(Volts)

High Level

(Volts)

Timing

(Microseconds)

Input Voltage and Current

1

+16.5 to –5 Vil <= 1.35 @ 1mA Vih >= 3.15 @ 1mA

Trigger Latency

3

Tlin

5

Positive Assertion

Tinh

2

Negative Assertion Period

Tinl

2

Trigger Recovery Time

Trt

Tinx orTrt > 50

1

Typical high-level leakage current is 1.15 mA @ 16.5V DC.

2

All voltages are with respect to the associated return signal.

3

Trigger latency is the maximum time from trigger receipt to when the response begins.