beautypg.com

AMETEK ReFlex Programming Manual User Manual

Page 80

background image

ReFlex Power™ Programming Manual

DC Module Remote Programming

76

M380056-03 Rev M

There may be additional commands added as the product is applied.
The non-LIST commands that interact with LISTs during creation are:

OUTP:ISOL:DEF

OUTP:SENSE:DEF

OUTP:STATE

OUTP:POL

SOUR:CURR <+NRf>

SOUR:CURR:PROT <+NRf>

SOUR:CURR:PROT:TRACK

SOUR:VOLT <+NRf>

SOUR:VOLT:PROT <+NRf>

SOUR:VOLT:PROT:TRACK

SOUR:UNDERVOLT:PROT <+NRf>

SOUR:UNDERVOLT:PROT:TRACK

TRIG:TRIG

TRIG:INP , OUTP

TRIG:OUTP , INP

TRIG:INP

TRIG:OUTP

TRIG:INPut:SLOPe [POSitive | NEGative | BOTH | NONE]

TRIG:OUTput:SLOPe [POSitive | NEGative | BOTH]

TRIG:WIDTh <+NRF>


See Section 3.15 for a summary and description of the LIST commands.

L

IST

T

RIGGER

G

ROUPS

All ReFlex Power™ high power and low power DC power modules can be
programmed to respond to the common trigger buss. The response to the
trigger or triggers allows a complex cross module type tightly timed sequence
to result. All this on a single module basis there is little new, the novel part is
to establish a trigger sequence that crosses several modules.

One new concept is to assign one or more power modules one or more
trigger pulses from a pulse sequence. If the pulse sequence is very tightly
timed and well described, the result is a complex well-timed sequence of
events. The following figure and associated table describes this concept.

1

2

3

4

5

6

Figure 3-9. Group Pulse Sequence