ReFlex Power™ Programming Manual

Load Module Remote Programming

112

M380056-03 Rev L

R

EADBACK

F

UNCTIONS

Actual measured voltage, power and current

Voltage, current and resistance settings

Soft voltage, power and current limits

Status and Accumulated Status registers

Programming error codes

Fault codes

Manufacturer, power supply model, serial number, and firmware

version identification

5.3

POWER-ON CONDITIONS

Table 5-1 presents the power-on conditions for the Active Loads.

Table 5-1. Load Power-on Conditions

Condition

Default

Current

0 Amps (initial power–on current). Also see

CAL:INIT:CURR

Soft Voltage Limit

Model maximum voltage

Soft Current Limit

Model maximum current

OVP Trip Voltage

Model maximum voltage +7% (initial power–on OVP).
See

CAL:INIT:VOLT:PROT

Input

OFF, relays open

Grouped

No Modules Grouped (example paralleled)

Soft Power Limit

Model power limit