beautypg.com

Toa M-864D Ver.2.2.0 User Manual

Page 68

background image

68

10. Scale Setting Button

Clicking this button while the filter control field

is in graph display mode displays the dialog for

setting the graph’s scale.

A. Minimum frequency settings

B. Maximum frequency settings

C. Maximum amplitude settings

E. Step settings

D. Minimum amplitude

settings

a. Minimum frequency Settings

Sets the minimum frequency for graph display

(i.e. sets the left edge of the graph).

The downward pointing triangle button

decreases the frequency and the upward

pointing triangle button increases the

frequency.

Clicking the frequency indication in the center

opens the dialog for frequency entry.

B. Maximum frequency Settings

Sets the maximum frequency for the graph

display (i.e. sets the right edge of the graph).

The downward pointing triangle button

decreases the frequency and the upward

pointing triangle button increases the

frequency.

Clicking the frequency indication in the center

opens the dialog for frequency entry.

C. Maximum amplitude Settings

Sets the maximum amplitude for the graph

display (i.e. sets the upper limit of the graph).

The downward pointing triangle button

decreases the amplitude and the upward

pointing triangle button increases the

amplitude. The amplitude varies by values set

in the Step settings each time the button is

clicked.

Clicking the amplitude indication in the center

opens the dialog for amplitude entry.

D. Minimum amplitude Settings

Sets the minimum amplitude for the graph

display (i.e. sets the lower limit of the graph).

The downward pointing triangle button

decreases the amplitude and the upward

pointing triangle button increases the

amplitude. The amplitude varies by values set

in the Step settings each time the button is

clicked.

Clicking the amplitude indication in the center

opens the dialog for amplitude entry.

e. Step Settings

Sets the spacing between amplitude scale

lines in the graph display.

Set step values are also used as spacing for

the amplitude set with the triangle buttons in

the maximum and minimum amplitude settings

of Items (C) and (D) above.

11. Q Indication Button

Used to switch the filter point’s Q indication

method.

The following three methods are available:

(1) Numerical indication

Q values are indicated by a numerical figure.

(2) Oct/band fractional indication

The value of the octave bandwidth

corresponding to the Q value is indicated by a

fractional value.

(3) Oct/band numerical indication

The value of the octave bandwidth

corresponding to the Q value is indicated by a

numerical figure.

Example: When the Q value is 4.318

Numerical indication: 4.318

Oct/band fractional indication:

1/3 oct/band

Oct/band numerical indication:

0.333 oct/band

12. Grouping Button

Sets grouping within the ARC box.

On ARC measurement completion, the measurement

target ARC boxes are automatically grouped,

cancelling already-set grouping on any of these

boxes, if there was. Actual operation filter data,

measurement parameters, and the filter data

created by ARC measurement are interlocked

among the grouped ARC boxes.