14. SPeCIfICatIoNS
14.1. Software Specification
14.1.1. Preset Memory
16 memories
14.2. Setting Items, Setting ranges, and Default Settings
14.2.1. Unit data
Setting Item
Setting Range
Default Setting
Remarks
Online Setting Storable in
Preset Memory
Unit Name
20 alphanumeric
characters
IP Address
IPv4
192.168.14.1
Subnet Mask
IPv4
255.255.255.0
Default Gateway
IPv4
0.0.0.0
External Control port
number
3000 to 49151
3000
+1: Level meter
14.2.2. Channel data
Setting Item
Setting Range
Default Setting
Remarks
Online Setting Storable in
Preset Memory
Unit Name
20 alphanumeric
characters
Example:
Mono In: 1, Stereo
In: 1, Mono Out: 1,
Rec out: L
14.2.3. Signal processing box
[Gain settings]
Setting Item
Setting Range
Default Setting
Remarks
Online Setting Storable in
Preset Memory
Phantom Power
ON, OFF
OFF
PAD
PAD OFF, PAD ON
PAD ON
LCF ON/OFF
ON, OFF
ON
LCF Cutoff Frequency 20 to 20 k (Hz),
1/24 octave steps
100
LCF Slope
12 dB/oct (fixed)
–
–
–
Gain Volume
PAD OFF:
+15 to +60 (dB), 1 dB
steps
PAD ON:
0 to +18 (dB), 1 dB
steps
PAD OFF: +15 (dB)
PAD ON: 0 (dB)