11.4. Preset Memory Settings

Select [Config Preset Memory Setting] in the Menu view to display the preset Memory settings screen.

(1) Preset Memory No.

(1) (2)

(3)

(2) Preset Memory name

(3) Cross-fade time settings

(4) Primary Reference Preset No.

selection button

(5) Preset Link setting

[Name and Cross-fade time Settings]

Set the name and cross-fade time for each Preset Memory.

[Primary reference Preset No. Setting]

1. Preset Memory No.

The Preset Memory Number is displayed.

2. Preset Memory Name

The name of each Preset Memory is displayed.

Click on the button to enter the Preset Memory

name.

3. Cross-fade time Settings

Displays cross-fade time for each Preset Memory.

The downward-pointing triangle button shortens

the cross-fade time, and the upward-pointing

triangle button lengthens the cross-fade time.

The triangle buttons located in the “ALL” section

can be used to change cross-fade times for all

Preset Memories simultaneously.

4. Primary reference Preset No. Selection Button

The Preset Memory number is displayed.

The button corresponding to the Preset Memory

number in effect when the power is switched ON is

displayed in orange.

Click on the button to set the Preset Memory

number.

When [Resume] button is clicked to select, the

M-864D is activated in the status* just before the

power was switched OFF.

When any button other than [Resume] button is

selected, the corresponding Preset Memory is

recalled when the power is switched ON.
* Preset Memory that had been recalled just before

the power was switched OFF is loaded when the

power is switched ON. If the Preset Memory was

being edited at power-off, the M-864D is activated

in the status that the Preset Memory is in edit.

[Preset Link Setting]

5. Preset Link Setting

Displays the IP address of the unit that functions

as the master unit interlocking Preset Memory with

other units.

Click on the IP address indication to enter the IP

address.

To interlock the Preset Memory with other units,

designate the IP address of the unit that functions

as the master interlock unit.

Notes

When the Preset Memory is not interlocked with

other units, set the IP address to the initial value

(0,0,0,0).

• The units that can be interlocked are the M-864D

and the DP-SP3.

Settings to be stored in the Preset Memories are set parameters of all setting items in the “Signal processing