Cautions at the time of grouping – Toa M-864D Ver.2.2.0 User Manual
Page 109

109
1
None
1
1
1
1
2
None
1
2
1
1
1
2
None
1
Recalls Preset memory 2.
The fader value is maintained
by the Change Safe function.
The fader value and grouping
number are switched to those
saved in Preset memory 2.
0 dB
0 dB
0 dB
–30 dB
Preset memory number
Change Safe layer
Channel
Change Safe layer
Grouping number
Fader
Both faders belong to
the same grouping
number, but indicate
different values.
Changing the fader value for one of the two faders in this state
causes both fader values to be matched by the grouping function.
12.3. Cautions at the time of grouping
Caution should be taken when assigning the Change safe function to the faders, PEQs, and ARC equipped
with grouping function.
If parameters set for the Change Safe and those not are grouped in the same grouping number, both set and
unset parameter values may be different due to the Change Safe function. (Refer to the example as shown
below.)
In such cases, review the settings according to usages, then cancel the grouping or assign the parameters
belonging to the same grouping number to the same Change safe layer.
[Example when grouped faders indicate different values]