[Channel name]

Displays the channel name.

[Level meter]

Indicates the signal level with a bar graph.

The post-gain processing level is displayed for the monaural input, and the post-Trim processing level for the

stereo input, and the pre-attenuator processing level for both monaural and recording outputs.

6.4. Contact Monitor View

Monitors the unit’s contact input and output statuses. Only displayed while in online mode.

Displays the functions allocated to each contact terminal and terminal status.

Function allocated to the contact input terminal

Function allocated to the contact output terminal

Contact No.

Contact No.

Contact input terminal status

Contact output terminal status

Break contact is displayed in black, and make contact is displayed in yellow.

Break:

Make:

For function allocations to each contact input and output, see

p. 81, “REMOTE SETTINGS.

Channel kind

Mono In, Stereo In,

Mono Out

Rec Out

Signal level

+18 dB to Peak: Red

+4 dB to Peak: Red

+6 to +18 dB: Yellow −8 to +4 dB:

Yellow

Under +6 dB: Green Under −8 dB:

Green