2 general information, 3 warranty – Reznor RECC Unit Installation Manual User Manual
Page 3

Form I-MAPSIII&IV, P/N 222917R9, Page 3
Models Description
RCB,
RCC
Makeup Air Cooling Packaged System, 1000-13000 CFM
RDCB,
RDCC
Makeup Air Cooling Packaged System, 1000-13000 CFM, with Gas
Heat Section (400-1600 MBH)
RECB,
RECC
Makeup Air Cooling Packaged System, 1000-13000 CFM, with
Electric Heat Section (10 - 180 kw)
RDB,
RDC
Makeup Air Cooling and Re-heat Pump Reheat Cycle Packaged
System, 1000-13000 CFM
RDDB,
RDDC
Makeup Air Cooling and Re-heat Pump Reheat Cycle Packaged
System, 1000-13000 CFM, with a Gas Heat Section (100-1600 MBH)
REDB,
REDC
Makeup Air Cooling and Re-heat Pump Reheat Cycle Packaged
System, 1000-13000 CFM, with Electric Heat Section (10 - 180 kw)
JHUP
Optional Curb Section with a 250 or 300 MBH Gas-Fired Duct
Furnace installed with a MAPS
®
unit with a Size 250 or 700 Heat
Section to provide 500 or 1000 MBH of heat
WARNING
Gas-fired appliances are not designed for use in
hazardous atmospheres containing flammable vapors
or combustible dust, in atmospheres containing
chlorinated or halogenated hydrocarbons, or in
applications with airborne silicone substances.
WARNING
Should overheating occur, or the gas supply fail to shut
off, shut off the manual gas valve to the appliance before
shutting off the electrical supply.
WARNING
Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and replace any gas control that
has been under water.
Warnings for MAPS
®
Units with a Gas Heat
Section
1.2 General
Information
This booklet includes installation and operation information. Before beginning any pro-
cedure, carefully review the information, paying particular attention to the warnings.
If you do not have knowledge of local requirements, check with the local agencies who
might have requirements concerning this installation. Become familiar with the installa-
tion requirements of your particular model and make preparations for necessary sup-
plies, equipment, and manpower.
Handling of the R-410A refrigerant should only be performed by a certified HVAC tech-
nician in compliance with all codes and requirements of authorities having jurisdiction.
The instructions in this manual apply to the following MAPS
®
models:
1.3 Warranty
Refer to limited warranty information on the warranty form in the "Literature Bag"
shipped with this system. If an optional extended warranty applies, keep the extended
warranty information for future reference and verification of warranty.
- REDB Unit Installation Manual RECB Unit Installation Manual RDDC Unit Installation Manual RDCC Unit Installation Manual RDDB Unit Installation Manual RDCB Unit Installation Manual RDC Unit Installation Manual RCC Unit Installation Manual RDB Unit Installation Manual RCB Unit Installation Manual REDC Unit Installation Manual MAPSIV Unit Installation Manual MAPSIII Unit Installation Manual