Maxim Integrated 71M6513H Power Meter IC Family Software User Manual
Page 78
71M651x Software User’s Guide
XRAM
Address
Name
Description
0x2F
Wh
Total Watt hours consumed (imported)
0x31
Whe
Total Watt hours generated (exported)
0x33
VARh
Total VAR hours consumed
0x35
VARhe
Total VAR hours generated (inverse consumed)
0x37
VAh
Total VA hours
0x39
Wh_A
Total Watt hours consumed through element 0
0x3B
Whe_A
Total Watt hours generated (inverse consumed) through element 0
0x3D
VARh_A
Total VAR hours consumed through element 0
0x3F
VARhe_A
Total VAR hours generated (inverse consumed) through element 0
0x41
VAh_A
Total VA hours in element 0
0x43
Wh_B
Total Watt hours consumed through element 1
0x45
Whe_B
Total Watt hours generated (inverse consumed) through element 1
0x47
VARh_B
Total VAR hours consumed through element 1
0x49
VARhe_B
Total VAR hours generated (inverse consumed) through element 1
0x4B
VAh_B
Total VA hours in element 1
0x4D
Wh_C
Total Watt hours consumed through element 2
0x4F
Whe_C
Total Watt hours generated (inverse consumed) through element 2
0x51
VARh_C
Total VAR hours consumed through element 2
0x53
VARhe_C
Total VAR hours generated (inverse consumed) through element 2
0x55
VAh_C
Total VA hours in element 2
Table 5-10: MPU Accumulation Output Variables (6513)
MPU VARIABLES INDEPENDENTLY CONTROLLING THE SECOND CURRENT CHANNEL
The 6511 Demo Code revision 3.05 offers independent scaling and creep suppression parameters for the second
current channel (phase B). This is useful for meter configurations where different sensors are used for the primary and
secondary channel. An example for this configuration would be a meter using a CT for phase A and an additional re-
sistive shunt for phase B to counter tampering. In most cases, the input voltage at the IA and IB inputs generated by
the current flowing through both sensors will not be identical due to the differing characteristics of the sensors. In
order to enable comparative measurements and true application of tariffs, Demo Code 6511 revision 3.05 offers a set
of variables used to scale the IB channel (phase B).
The variables added in 6511 Demo Code revision 3.05 are shown in Table 5-11.
Revision 2.4
TERIDIAN Proprietary
78 of 137
© Copyright 2005-2006 TERIDIAN Semiconductor Corporation