beautypg.com

Maxim Integrated 71M6513H Power Meter IC Family Software User Manual

Page 78

background image

71M651x Software User’s Guide

XRAM

Address

Name

Description

0x2F

Wh

Total Watt hours consumed (imported)

0x31

Whe

Total Watt hours generated (exported)

0x33

VARh

Total VAR hours consumed

0x35

VARhe

Total VAR hours generated (inverse consumed)

0x37

VAh

Total VA hours

0x39

Wh_A

Total Watt hours consumed through element 0

0x3B

Whe_A

Total Watt hours generated (inverse consumed) through element 0

0x3D

VARh_A

Total VAR hours consumed through element 0

0x3F

VARhe_A

Total VAR hours generated (inverse consumed) through element 0

0x41

VAh_A

Total VA hours in element 0

0x43

Wh_B

Total Watt hours consumed through element 1

0x45

Whe_B

Total Watt hours generated (inverse consumed) through element 1

0x47

VARh_B

Total VAR hours consumed through element 1

0x49

VARhe_B

Total VAR hours generated (inverse consumed) through element 1

0x4B

VAh_B

Total VA hours in element 1

0x4D

Wh_C

Total Watt hours consumed through element 2

0x4F

Whe_C

Total Watt hours generated (inverse consumed) through element 2

0x51

VARh_C

Total VAR hours consumed through element 2

0x53

VARhe_C

Total VAR hours generated (inverse consumed) through element 2

0x55

VAh_C

Total VA hours in element 2

Table 5-10: MPU Accumulation Output Variables (6513)

MPU VARIABLES INDEPENDENTLY CONTROLLING THE SECOND CURRENT CHANNEL

The 6511 Demo Code revision 3.05 offers independent scaling and creep suppression parameters for the second
current channel (phase B). This is useful for meter configurations where different sensors are used for the primary and
secondary channel. An example for this configuration would be a meter using a CT for phase A and an additional re-
sistive shunt for phase B to counter tampering. In most cases, the input voltage at the IA and IB inputs generated by
the current flowing through both sensors will not be identical due to the differing characteristics of the sensors. In
order to enable comparative measurements and true application of tariffs, Demo Code 6511 revision 3.05 offers a set
of variables used to scale the IB channel (phase B).

The variables added in 6511 Demo Code revision 3.05 are shown in Table 5-11.

Revision 2.4

TERIDIAN Proprietary

78 of 137

© Copyright 2005-2006 TERIDIAN Semiconductor Corporation