71M651x Software User’s Guide
Timer/Counter Control Register (TCON)
MSB
LSB
tf1
tr1
tf0
tr0
ie1
it1
ie0
it0
Table 6-47: The TCON Register
Bit
Symbol
Function
TCON.7
tf1
Timer 1 overflow flag
TCON.6
tr1
Not used for interrupt control
TCON.5
tf0
Timer 0 overflow flag
TCON.4
tr0
Not used for interrupt control
TCON.3
ie1
External interrupt 1 flag
TCON.2
it1
External interrupt 1 type control bit
TCON.1
ie0
External interrupt 0 flag
TCON.0
it0
External interrupt 0 type control bit
Table 6-48: The TCON Bit Functions
Interrupt Request Register (IRCON)
MSB
LSB
iex6
iex5
iex4
iex3
iex2
Table 6-49: The IRCON Register
Bit
Symbol
Function
IRCON.7
-
IRCON.6
-
IRCON.5
iex6
External interrupt 6 edge flag
IRCON.4
iex5
External interrupt 5 edge flag
IRCON.3
iex4
External interrupt 4 edge flag
IRCON.2
iex3
External interrupt 3 edge flag
IRCON.1
iex2
External interrupt 2 edge flag
IRCON.0
-
Table 6-50: The IRCON Bit Functions
Only tf0 and tf1 (timer 0 and timer 1 overflow flag) will be automatically cleared by hardware when the service
routine is called (Signals t0ack and t1ack – port ISR – active high when the service routine is called).