beautypg.com

1 setting of voltage and frequency characteristics, 1 maximum frequency [fh, 1 maximum frequency [fh] -4 – Toshiba VF-SX User Manual

Page 69: Toshiba, 1 maximum frequency

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

9-4

TOSHIBA

9.1 Setting of Voltage and Frequency Characteristics

The characteristics of the output voltage vs.the output frequency are adjustable.

The standard pattern is as shown in Figure 9.1.

If necessary, adjust the Voltage/Frequency characteristics for the following

special applications:

1. To operate the driven load above 80 HZ.

2. To increase startup torque.

3. To adjust for a base frequency other than 50 HZ or 60 HZ.

9.1.1 Maximum Frequency

[FH]

The maximum frequency [ FH] can be set from 30 to 240 HZ.

Output

Frequency

Frequency
Setting

Signal

10VDC

5VDC
20mADC

Figure 9.1 Setting the Maximum Frequency

The maximum frequency

[FH]

cannot be changed during operation. Stop the

inverter to adjust this parameter.