4 retry [rtry, Caution, 4 retry [t t r y ] -8 – Toshiba VF-SX User Manual

Page 115: E 5 t p, Toshiba, D b t, 4 retry [ r t r y

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

11-8

TOSHIBA

ST

cc

SS1 SS3

(EX)

h o h o h

F R ST

Switch Switch Switch

EX

Switch

Figure 11.2 Forward, Reverse, and Emergency Stop

Switches

11.3.3

Emergency DC Injection Braking

Stop Controi Time [f c/b t]

When

[E 5 t P]

-

P,

(emergency DC injection braking stop is selected) and DC

injection braking is not retired during normal stop, set the DC injection

braking time to [

d b t ]

.

0 .

See Section 11.2 in this Chapter for instructions to set parameters [

d b U ]

and

[ d b t } .

11.4 Retry [ r t r y ]

The retry function allows the drive to perform an auto-restart, when this feature

is desirable and applicable. The retry feature operates after a protective

function or parameter trips the drive.

CAUTION:

Before using the retry function confirm that there will be no problems with
the load or application when an automatic restart occurs. Certain large

inertia loads, or loads requiring large torque boost to start may not work

properly with the retry feature. Also, personnel safety is an obvious
consideration.