TABLE 8-5: STARTING THE DRIVE FROM THE TOUCHPAD

Procedure

Operation

Power On

Turn on power to the Inverter with the HCCB. If the

display shows

[ O F F ] ,

the proper operating conditions

are not set, and operation will not be possible. Close
the connection between terminals ST and CC. Operation is

possible if r O . O l is displayed.

IPANEU 1

|

pq

^

e

[

IPANEU 1

Change to Panel Control by pushing the key. The

"PANEL CONTROL" LED will turn on. Operation from the

IMNEU 1

touchpad will now be possible. If the lf55Z!l button is
pushed again, the light will turn off, and touchpad

control will be deactivated.

|

ei

^

er

[

Adjustment of the operating frequency/speed is

accomplished from the and keys on the touchpad.

When these keys are depressed the "PANEL CONTROL" light

will flicker, indicating the numerical value in the LEO

display is changing. When the desired frequency is shown

press the key and the display will alternately show

F C

and the frequency, in order. When the key is

depressed the assigned running frequency is stored in the

drive’s memory.

pp U N j

Depressing this key will energize the output circuits.
The frequency display will begin to increase at the
programmed acceleration rate, and the motor will begin to
rotate.

I^E °E

t

|

Depressing the I

m

M

i

I key will cause the inverter to ramp

the load to a stop at the programmed deceleration rate.

CAUTION:

If the power switch Is turned OFF during step 4 above, the motor will coast

to stop. However, DO HOT stop the Inverter In this fashion unless there is

an emergency. Always avoid starting and stopping the Inverter from the

power switch.