Sx drive, Toshiba – Toshiba VF-SX User Manual

Page 32

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

TOSHIBA

6-5

Example 4: To set the operation frequencies, and conduct forward/reverse run,

decelerating stop and coasting stop with external signals.

SX DRIVE

Figure 6.4

Setting: In the parameter group

[0

f~.

S t

] the

Comand Mode Selection

is set

to 3 (control terminal or touchpad input), and the

Frequency Setting Mode

Selection

to 3 (control terminal or touchpad input). These are the standard

default settings. To carry out automatic operation with case 3 (4-20mA signal)

from remote controls and manual operation with the case 1 potentiometer set the

RR Terainal Input Prioritization

to 1 and

IV Input

to 1. Manual setting values

are then accepted if the potentiometer is turned to generate a voltage between

RR and CC. Emergency stop is possible from the touchpad when the

pressed twice.

In Figure 6.4 above:

key is

1.

2

.

3.
4.

5.

Incoming power is 200-230 volts, three phase, 50 or 60 Hz.

Speed reference signal #1 is a potentiometer.
Speed reference signal #2 is a O-IOV DC control input signal.
Speed reference signal #3 is a 0-20mA, 4-20mA, or 0-5V DC control

input signal.

Jumpers JPl and JP2 are shown in their approximate location on the

internal printed circuit board, behind the front cover.