TOSHIBA
7-7
TABLE 7-5: PARAMETER GROUP
[ G C . P T ] -
PROTECTIVE FUNCTION PARAMETERS
1 Fwictlon
Title
Adjuataent
Range
unit
Ship-
sent
User
Setting
Page
1 Regenerative
1 Discharge Braking
1 Selection
P b
0: Regenerative Discharge
Braking Disengaged
1: Regenerative Discharge
Braking Engaged without
Overload Protection
2: Regenerative Discharge
Braking Engaged with
Overload Detection
0
11-2
1 Overvoltage Liniting
1 Action Selection
O P 5 5
0: Engaged
1: Disengaged
0
11-2
DC Undervoltage
Startva» Frequency
d b P
0 -• 10
0.1 KZ
0
11-^
(Other than 0) (*)
DC Injection Braking
Voltage
DC Injection Braking
Tiae
d b u
d b t
0 -* 20
0 •• 5
1 X
0.1 Sec
0
0
11-A
11-A
Eaiergency Stop
E S b P
0: Coasting Step
1: Decelerating Stop
2: Eaergency DC Injection
Braking Stop (EDB)
0
11-6
(2> Eaergency DC
Injection Braking
Stop Control Tiaie (*)
E d b b
0 - 10
0.1 Sec
0.1
11-8
Retry Selection
r k r d
0: OFF
1: ON
0
11-8
Power Control
Function Selection
U u C
0: OFF
1: on
0
11-10
Electronic Thenaal
Protective Level
E H r
10 •• 100
1 X
100
11-11
Stall Prevention
Activation Level
S E L
10 -- 150,
(200: Mon-operating)
1 X
150
11-11
Electronic Theraal
Protection
Characteristic
Selection
D i n
0: Standard Motor without SS
1: Standard Motor with SS
2: VF Motor without SS
3: VF Motor with SS
(Mete: SS - Soft Stall)
0
11-11
Trip Retention
Selection
E r C L
0: Clear with Power OFF
1: Retain Even with Power
OFF
0
11-13
The parameters marked with an asterisk (*) will be displayed as detailed parameters
only when the parameter in the row immediately above this function is selected for
adjustment or review.