beautypg.com

Toshiba 16-5, R c c – Toshiba VF-SX User Manual

Page 156

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

TOSHIBA

16-5

TABLE 16-2: (Continued)

Error Symptoms

Possible Cause »nd Remedy

Motor does not rotate.

1. Incorrect wiring, open circuit, power

failure at the input, output, or power

line. Confirm that CHARGE lamp is on.

2. When operating from the touchpad confirm

that the “PANEL CONTROL" LED is on.

jPANEU I

Press the

key as required.

3. Confirm that the operating frequency is

set to desired frequency.

4. Confirm that terminal ST-CC is shorted.

Short terminals if necessary.

5. Check to see if a trip has occurred, or

if the auto-restart preparation is on. If

tripped, remove cause and reset drive.

6. The load on the motor is too heavy.

Decrease the load or increase the rating

of the drive.

7. If

P

is displayed on the LED monitor the

input voltage is too high. Reduce

voltage to 240 VAC or less._______________

The motor acceleration
or deceleration is not
smooth.

1. The setting for the acceleration time

[ R C C

]

and deceleration time [rf

f C]

is too short.
Lengthen the acceleration time or the

deceleration time.

The motor speed is too

high or too low.

1. The motor voltage specifications are not

appropriate. Adjust the motor voltage to
the specifications.

2. The motor terminal voltage is low. Check

the output voltage decrease and output
voltage adjustment set values. Increase the

wire size if necessary.

3. The increased deceleration rate for the

gear, etc. is not correct. Check the

increased deceleration rate for the gear,

etc.

4. The output frequency setting is not correct.

Check the setting of the output frequency

range.

5. Adjust the carrier frequency.________________

The motor "pulses’

during operation.

1. The load is too heavy or too light.

Decrease the load variation. Hake sure it

matches the drive characteristics.

2. The inverter and motor rating values do not

match. Make sure the load matches the drive

characteristics.