TOSHIBA

APPENDIX 1 — TABLE OF TRIP CODES AND WARNING CODES

Display

Trip Code Contents

n S r r

No Error (Only Appears in Past Error Displays)

O C I

Overcurrent Trip (OC) During Acceleration

о с г

Overcurrent Trip (OC) During Deceleration

O C 3

Overcurrent Trip (OC) During Normal Dperation

O C L

Overcurrent Trip on Load Side at Start-up (Check Output
Terminals)

O C R

Overcurrent Trip on Alarm at Start-up (Check Output Device -

GTR’s)

O P

Overvoltage Trip in OC Circuit (OP)

о р г

(Overvoltage Trip in DC Circuit During Deceleration (OP)

O H

Inverter Overheating Trip (OH)

O L

Motor Overload Trip (OL)

E

Emergency Stop

E E P

EEPROM Abnormality (Adjustment or Other Data)

E r r P

RAM Abnormality

Е г г З

ROM Abnormali ty

UIL

Overload Trip in Discharge Resistor for Regenerative
Discharge Braking

Display

Warning Code Contents (Does NOT Trip Drive)

P O P E

Undervoltage Display

r b r y

Display During Retry

E r r 1

External Frequency Setting Error

C L r

Indication of Clear

E O F F

Indication of Emergency Stop

C b r L

Indication of Control for Coasting Stop

H 1

Set Value has Reached Upper Limit, and Cannot be Set Higher

L O

Set Value has Reached Lower Limit, and Cannot be Set Lower