CAUTION:

The Emergency Stop command is a command to forcibly stop the operation by

depressing the inverter unit keys on the touchpad when the drive is not

controlled from the touchpad. This cannot be prohibited by any setting of
the command mode. The emergency stop will be regarded as a trip and will
be registered as a past error in the trip history section of the drive

memory.____________________________________________________________________

11.3.2 Emergency Stop Using Remote Control Signals

Emergency stop may also be initiated from control signals connected to the proper

terminal blocks. The following instructions explain this procedure.

Emergency Stop from Remote Control:

1. Connect an "emergency stop” switch between EX-CC on the control circuit

terminal block as shown in figure 11.2

2. Confirm that the input terminal selection is set to ^

o r

3 .

(Parameter

[ I t b ] - 3

o r

3 . )

This insures the drive will accept this

remote signal. (The factory default setting for this parameter

i s [ I t b ] - 0 . )

3. Confirm that the "PANEL CONTROL" lamp is not ON. Turn off the "PANEL

CONTROL" lamp by pressing the

key.

4. The type of emergency stop

[f 5 t P]

can be selected with the operation

panel. See Table 11-3 above.

5. When the EX terminal is turned ON, emeroency stop will be activated according

to the parameter selected in

[E 5 fc P],

the inverter will trip,

([f

] will

flicker on the LED display) and the Fault (FL) relay will operate.