2 display modes, 2 display modes -4, Toshiba – Toshiba VF-SX User Manual
Page 49: L“°"l
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
8-4
TOSHIBA
The "RUN" key is used to start operation of the drive,
is valid ONLY when the "PANEL CONTROL" LED is lit.
It
S T O P
R E S E T
The "STOP/RESET" key stops operation of the drive, when the
drive is in "PANEL CONTROL" mode. Emergency stop operation is
possible by pressing this key TWICE, when the drive is in any
other mode. The inverter is reset from this key (depress for 1
second, minimum) after a trip.
O Hz O SEC
O PANEL CONTROL
o*
This 7 segment, 4 digit LED display shows
operating frequency in DRIVE mode, the status of a
variety of data in the MONITOR mode, the title of the
parameter groups, and the values of these parameters
in the PROGRAMMING mode. In the event of a trip, the
cause of this trip is displayed. The "Hz", "SEC",
"X", or "PANEL CONTROL" LED’s will be illuminated as
appropriate in all modes.
8.2 Display Modes
The Toshiba Model SX inverter has four types of operation and display modes, as
shown below:
1. Drive Mode
2. Monitor Mode
3. Programming Mode
4. Jogging Mode
For basic drive operation, this section of the manual will discuss all of these
modes as they apply when using the touchpad to operate the drive. There are many
options for remote control of the drive discussed in later chapters of this
manual.
Enter Monitor Mode by pressing the
l“°"l
key. To re-enter Drive Mode press thpl
I
key again. Enter Programming Mode by pressing the s key. To return to Drive
Mode press the E^Z] key again. If there is no input within 3 seconds from
depressing the
or
the drive will automatically return to Drive Mode
and display the frequency.