beautypg.com

Toshiba 14-3 – Toshiba VF-SX User Manual

Page 144

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

TOSHIBA

14-3

TABLE 14-1 (Con’t)

1 Acceleration and
1 Deceleration Time

0.1 - 3600 seconds, Acc./Dec. time,

1/2 changeover, S-Character Acc./Dec. pattern

selection

1 DC Injection Brake

Braking start frequency (0-10 HZ), Braking voltage

(0-20%), Braking control time (0-5 sec.)» Emergency

DC injection braking stop control time

(0-10 sec.), all adjustable

Protective Functions

Stall prevention, current limit, overcurrent,

overcurrent during braking, load side short circuit,

(detection), undervoltage, momentary power failure,

power control function, overload due to electronic

thermal, phase overcurrent at start, load side

overcurrent at start, braking resistance overload,
cooling fin overheating, emergency stop.

Electronic Thermal

Characteristics

Changeover of standard motor/VF motor for constant

torque adjustment of electronic thermal stall
prevention operation level

Reset

Reset when la contact point is closed , or with
panel. Set trip retention and clear.

4-D1git, 7-Segment LED

Display of output frequency, OFF, alarm trip case ,

parameter name, data and universal units.

■Charge" Indication LED

Main circuit capacitor charge indication.

Fault Detection Signal

Output of 1C contact point (during 250 VAC - 2A or

30VDC - 2A resistance load, and 1.5A rating for

induction load.)

Low Speed, Speed
Reached, Upper and Lower
Limit Freguency Signal

Open collector output (24 VDC, maximum of 50 HA), 2

points.)

Frequency Meter and

Ammeter Output

1 mA DC full scale ammeter or 7.5 VDC-1 mA DC

voltmeter/rectifying AC ammeter

Enclosure

NEHA 1

Cooling Method

Self cooled 1 HP and smaller. Fan cooled 2 HP and
larger.

Col or

Hunsell symbol N1.5

Service Environment

Indoor, altitude under 1000 meters (3300 ft),

locations not in direct sunlight, nor where there Is

corrosive gases or steam.

Ambient Temperature

-10 to ■i'40 deg C. (Maximum 50 deg C when heating
caution plate is removed.)

Relative Humidity

90% or less, non-condensing

Vibration

0.5G or less (20-50 Hz), 0.1mm or less (50-100 Hz).