12.4 PWM Carrier Frequency

[ C F ] and

Motor Tone Selection

[C F 5]

The acoustic noise of the motor changes when the PWM carrier frequency is

changed. Changing the PWM carrier frequency Is usually effective in quieting

the mechanical vibration noise when a resonation occurs at the load machine motor

fan cover. Other system characteristics are also affected by the carrier
frequency.

The PWM carrier can be set between 0.5 kHZ and 3 kHZ.

Motor noise can also be changed by selecting "integral tone" as an option from

the motor tone selection table.

TABLE 12-1; MOTOR TONE PARAMETERS

[ C F 5

] Value

Function

0

Monotonous tone

1

Integral tone

The motor tone parameter

[C F 5

] cannot be changed until the drive has

NQI£i

been stopped.

12.5 Output Voltage Adjustment

[ P O U b ] and

Power Voltage Compensation Function

[ P R d J ]

The V/f characteristics can be set for a motor with a lower rated voltage by
using the output voltage reduction function. When the power voltage compensation

function is used , the output V/f characteristics are automatically compensated

to be constant even when the power voltage changes, so that the best V/f control

is possible at all times. However, an output voltage value greater than the

power voltage input value is not possible. This function is suitable for

machinery requiring a large start-up torque.

1. Output Voltage Reduction Function [

P O U b ]

The output voltage can be reduced proportionally to the input voltage.

The output voltage can be set between 0 and 100%.

2. Power Voltage Compensation Function [

P R d J ]

If this parameter is set to / the absolute value of the output voltage

can be set between 0 and 12056.