About Your System
45
Warning! No microcode
update loaded for
processor
n
Microcode update failed. Update the BIOS firmware.
See "Getting Help" on
page 185.
Warning: Embedded
RAID firmware is not
present!
Embedded RAID
firmware does not
respond.
See the RAID controller
documentation for
information about
installing or updating the
RAID firmware.
Warning: Embedded
RAID error!
Embedded RAID
firmware responds with
an error.
See "Troubleshooting a SAS
or SAS RAID Controller
Daughter Card" on
page 166. See the RAID
controller documentation
for information about
installing or updating the
RAID firmware.
Warning: The current
memory configuration
is not optimal. Dell
recommends a
population of 2, 4,
8, or 12 DIMMs.
DIMMs should be
populated
sequentially
starting in slot 1.
System has detected a
legal but non-optimal
population of DIMMs
(for example, 1 DIMM, 6
DIMMs, 4 DIMMs in
slots 1, 2, 5, and 6, etc.).
The system will run with
all memory accessible but
will experience sub-
optimal performance.
Populate 2, 4, 8, or 12
DIMMs sequentially
beginning with slot 1. See
"Memory" on page 107.
Write fault
Write fault on
selected drive
Faulty diskette,
optical/diskette drive
assembly, hard drive, or
hard-drive subsystem.
See "Troubleshooting a
Diskette Drive" on
page 160, "Troubleshooting
an Optical Drive" on
page 162, or
"Troubleshooting a Hard
Drive" on page 164.
NOTE:
For the full name of an abbreviation or acronym used in this table, see the
Table 1-7.
System Messages (continued)
Message
Causes
Corrective Actions
book.book Page 45 Monday, September 14, 2009 1:53 PM