Dell PowerVault DP600 User Manual
Page 42
42
About Your System
PCIe Training Error:
Embedded
Bus#
nn
/Dev#
nn
/Funcn
PCIe Training Error:
Slot
n
Faulty or improperly
installed PCIe card in the
specified slot.
Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" on
page 87. If the problem
persists, see "Getting Help"
on page 185.
PCI BIOS failed to
install
PCI device BIOS (Option
ROM) checksum failure
is detected during
shadowing. Loose cables
to expansion card(s);
faulty or improperly
installed expansion card.
Reseat the expansion cards.
Ensure that all appropriate
cables are securely
connected to the expansion
cards. If the problem
persists, see
"Troubleshooting
Expansion Cards" on
page 168.
Plug & Play
Configuration Error
Error encountered in
initializing PCI device;
faulty system board.
Install the NVRAM_CLR
jumper and reboot the
system. See Figure 6-1 for
jumper location. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 168.
Read fault
Requested sector not
found
The operating system
cannot read from the
diskette or hard drive, the
system could not find a
particular sector on the
disk, or the requested
sector is defective.
Replace the diskette.
Ensure that the diskette
and hard drive cables are
properly connected. See
"Troubleshooting a USB
Device" on page 151,
"Troubleshooting a
Diskette Drive" on
page 160, or
"Troubleshooting a Hard
Drive" on page 164 for the
appropriate drive(s)
installed in your system.
Table 1-7.
System Messages (continued)
Message
Causes
Corrective Actions
book.book Page 42 Monday, September 14, 2009 1:53 PM