About Your System
Error: Incorrect
memory
configuration. DIMMs
must be installed in
pairs of matched
memory size, speed,
and technology.
Mismatched or
unmatched DIMMs
installed; faulty or
improperly seated
memory module(s).
Ensure that all pairs of
memory modules are of the
same type and size and that
they are properly installed.
See "Memory" on page 107.
If the problem persists, see
"Troubleshooting System
Memory" on page 158.
Error: Memory
failure detected.
Memory size reduced.
Replace the faulty
DIMM as soon as
possible.
Faulty or improperly
seated memory
module(s).
See "Troubleshooting
System Memory" on
page 158.
!!*** Error: Remote
Access Controller
initialization
failure*** RAC
virtual USB devices
may not be
available...
Remote Access Controller
initialization failure
Ensure that the Remote
Access Controller is
properly installed. See
"Installing a RAC Card" on
page 114.
FBD training error:
The following branch
has been disabled:
Branch x
The specified branch
(channel pair) contains
DIMMs that are
incompatible with each
other.
Ensure that only Dell-
qualified memory is used.
Dell recommends
purchasing memory
upgrade kits directly from
www.dell.com or your Dell
sales agent to ensure
compatibility.
Gate A20 failure
Faulty keyboard
controller; faulty system
board.
See "Getting Help" on
page 185.
Table 1-7.
System Messages (continued)
Message
Causes
Corrective Actions