Dell PowerVault DP600 User Manual
Page 25
About Your System
25
E1414
CPU #
Thermtrip
Specified microprocessor is
out of acceptable
temperature range and has
halted operation.
See "Troubleshooting
System Cooling Problems"
on page 156. If the problem
persists, ensure that the
microprocessor heat sinks
are properly installed. See
"Troubleshooting the
Microprocessors" on
page 169.
NOTE:
The LCD continues
to display this message
until the system’s power
cord is disconnected and
reconnected to the AC
power source, or the SEL
is cleared using either
Server Assistant or the
BMC Management Utility.
See the Dell OpenManage
Baseboard Management
Controller User’s Guide
for
information about these
utilities.
E1418
CPU #
Presence
Specified processor is
missing or bad, and the
system is in an unsupported
configuration
See "Troubleshooting the
Microprocessors" on
page 169.
E141C
CPU Mismatch
Processors are in a
configuration unsupported
by Dell.
Ensure that your
processors match and
conform to the type
described in the
Microprocessor Technical
Specifications outlined in
your system’s Getting
Started Guide.
Table 1-6.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions
book.book Page 25 Monday, September 14, 2009 1:53 PM