Dell PowerVault DP600 User Manual
Page 23
About Your System
23
Table 1-6.
LCD Status Messages
Code
Text
Causes
Corrective Actions
N/A
SYSTEM NAME
A 62-character string that
can be defined by the user in
the System Setup program.
The SYSTEM NAME displays
under the following
conditions:
• The system is powered on.
• The power is off and
active POST errors are
displayed.
This message is for
information only.
You can change the
system string in the
System Setup program.
See "Using the System
Setup Program" on
page 47.
E1000
FAILSAFE,
Call Support
See "Getting Help" on
page 185.
E1114
Temp Ambient
Ambient system temperature
is out of acceptable range.
See "Troubleshooting
System Cooling
Problems" on page 156.
E1116
Temp Memory
Memory has exceeded
acceptable temperature and
has been disabled to prevent
damage to the components.
See "Troubleshooting
System Cooling
Problems" on page 156.
E1210
CMOS Batt
CMOS battery is missing, or
the voltage is out of
acceptable range.
See "Troubleshooting the
System Battery" on
page 154.
E1211
ROMB Batt
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery.
See "Replacing the SAS
RAID Controller
Daughter Card Battery"
on page 126, and
"Troubleshooting System
Cooling Problems" on
page 156.
E12
nn
XX
PwrGd
Specified voltage regulator
has failed.
See "Getting Help" on
page 185.
E1229
CPU # VCORE
Processor # VCORE voltage
regulator has failed.
See "Getting Help" on
page 185.
book.book Page 23 Monday, September 14, 2009 1:53 PM