Dell PowerVault DP600 User Manual
Page 41
About Your System
41
No boot sector on
hard drive
Incorrect configuration
settings in System Setup
program, or no operating
system on hard drive.
Check the hard-drive
configuration settings in
the System Setup program.
See "Using the System
Setup Program" on page 47.
If necessary, install the
operating system on your
hard drive. See your
operating system
documentation.
No timer tick
interrupt
Faulty system board.
See "Getting Help" on
page 185.
Northbound merge
error - The
following DIMM has
been disabled by
BIOS: DIMM x
The specified DIMM was
unable to establish a
successful data link with
the memory controller.
See "Troubleshooting
System Memory" on
page 158.
Not a boot diskette
No operating system on
diskette.
Use a bootable diskette.
PCIe Degraded Link
Width Error:
Embedded
Bus#
nn
/Dev#
nn
/Func
n
Expected Link Width
is
n
Actual Link Width is
n
Faulty or improperly
installed PCIe card in the
specified slot.
Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" on
page 87. If the problem
persists, see "Getting Help"
on page 185.
PCIe Degraded Link
Width Error: Slot
n
Expected Link Width
is
n
Actual Link Width is
n
Faulty or improperly
installed PCIe card in the
specified slot.
Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" on
page 87. If the problem
persists, see "Getting Help"
on page 185.
Table 1-7.
System Messages (continued)
Message
Causes
Corrective Actions
book.book Page 41 Monday, September 14, 2009 1:53 PM