Dell PowerVault DP600 User Manual
Page 30
30
About Your System
E1A18
PDB Ctrl
Cable
The power distribution
board control cable is
unseated, missing, or bad.
Ensure that the power
distribution board control
cable is seated properly. If
the problem persists,
replace the power
distribution board control
cable. See "Installing the
Power Distribution
Board" on page 142.
E2010
No Memory
No memory is installed in
the system.
Install memory. See
"Memory" on page 107.
E2011
Mem Config
Err
Memory detected, but is not
configurable. Error detected
during memory
configuration.
See "Troubleshooting
System Memory" on
page 158.
E2012
Unusable
Memory
Memory is configured, but
not usable. Memory
subsystem failure.
See "Troubleshooting
System Memory" on
page 158.
E2013
Shadow BIOS
Fail
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 158.
E2014
CMOS Fail
CMOS failure. CMOS RAM
not functioning properly.
See "Getting Help" on
page 185.
E2015
DMA
Controller
DMA controller failure.
See "Getting Help" on
page 185.
E2016
Int
Controller
Interrupt controller failure.
See "Getting Help" on
page 185.
E2017
Timer Fail
Timer refresh failure.
See "Getting Help" on
page 185.
E2018
Prog Timer
Programmable interval timer
error
See "Getting Help" on
page 185.
E2019
Parity Error
Parity error.
See "Getting Help" on
page 185.
Table 1-6.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions
book.book Page 30 Monday, September 14, 2009 1:53 PM