beautypg.com

Dell PowerVault DP600 User Manual

Page 30

background image

30

About Your System

E1A18

PDB Ctrl

Cable

The power distribution
board control cable is
unseated, missing, or bad.

Ensure that the power
distribution board control
cable is seated properly. If
the problem persists,
replace the power
distribution board control
cable. See "Installing the
Power Distribution
Board" on page 142.

E2010

No Memory

No memory is installed in
the system.

Install memory. See
"Memory" on page 107.

E2011

Mem Config

Err

Memory detected, but is not
configurable. Error detected
during memory
configuration.

See "Troubleshooting
System Memory" on
page 158.

E2012

Unusable

Memory

Memory is configured, but
not usable. Memory
subsystem failure.

See "Troubleshooting
System Memory" on
page 158.

E2013

Shadow BIOS

Fail

The system BIOS failed to
copy its flash image into
memory.

See "Troubleshooting
System Memory" on
page 158.

E2014

CMOS Fail

CMOS failure. CMOS RAM
not functioning properly.

See "Getting Help" on
page 185.

E2015

DMA

Controller

DMA controller failure.

See "Getting Help" on
page 185.

E2016

Int

Controller

Interrupt controller failure.

See "Getting Help" on
page 185.

E2017

Timer Fail

Timer refresh failure.

See "Getting Help" on
page 185.

E2018

Prog Timer

Programmable interval timer
error

See "Getting Help" on
page 185.

E2019

Parity Error

Parity error.

See "Getting Help" on
page 185.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

book.book Page 30 Monday, September 14, 2009 1:53 PM