Dell PowerVault DP600 User Manual
Page 31
About Your System
31
E201A
SIO Err
SIO failure.
See "Getting Help" on
page 185.
E201B
Kybd
Controller
Keyboard controller failure.
See "Getting Help" on
page 185.
E201C
SMI Init
System management
interrupt (SMI) initialization
failure.
See "Getting Help" on
page 185.
E201D
Shutdown
Test
BIOS shutdown test failure. See "Getting Help" on
E201E
POST Mem
Test
BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 158. If problem
persists, see "Getting
Help" on page 185.
E201F
DRAC Config
Dell remote access controller
(DRAC) configuration
failure.
Check screen for specific
error messages.
Ensure that DRAC cables
and connectors are
properly seated. If
problem persists, see your
DRAC documentation.
E2020
CPU Config
CPU configuration failure.
Check screen for specific
error messages.
E2021
Memory
Population
Incorrect memory
configuration. Memory
population order incorrect.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 158.
E2022
POST Fail
General failure after video.
Check screen for specific
error messages.
E2110
MBE DIMM ##
& ##
One of the DIMMs in the set
implicated by "## & ##"
has had a memory multi-bit
error (MBE).
See "Troubleshooting
System Memory" on
page 158.
Table 1-6.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions
book.book Page 31 Monday, September 14, 2009 1:53 PM