Dell PowerVault DP600 User Manual
Page 35
About Your System
35
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.
Table 1-7.
System Messages
Message
Causes
Corrective Actions
Alert! Redundant
memory disabled!
Memory configuration
does not support
redundant memory.
Installed memory
modules are not the same
type and size; faulty
memory module(s).
Ensure that all memory
modules are of the same
type and size and that they
are properly installed. See
"Memory" on page 107. If
the problem persists, see
"Troubleshooting System
Memory" on page 158.
Attempting to update
Remote
Configuration.
Please wait...
Remote Configuration
request has been detected
and is being processed.
Wait until the process is
complete.
BIOS Update Attempt
Failed!
Remote BIOS update
attempt failed.
Retry the BIOS update. If
problem persists, see
"Getting Help" on
page 185.
Caution! NVRAM_CLR
jumper is installed
on system board.
NVRAM_CLR jumper is
installed. CMOS has
been cleared.
Remove the NVRAM_CLR
jumper. See Figure 6-1 for
jumper location.
CPUs with different
cache sizes
detected!
Microprocessors with
different cache sizes are
installed.
Ensure that all
microprocessors have the
same cache size and that
they are properly installed.
See "Microprocessor" on
page 117.
Decreasing available
memory
Faulty or improperly
installed memory
modules.
See "Troubleshooting
System Memory" on
page 158.
book.book Page 35 Monday, September 14, 2009 1:53 PM