Dell PowerVault DP600 User Manual
Page 32
32
About Your System
E2111
SBE Log
Disable DIMM
##
The system BIOS has
disabled memory single-bit
error (SBE) logging, and will
not resume logging further
SBEs until the system is
rebooted. "##" represents
the DIMM implicated by the
BIOS.
See "Troubleshooting
System Memory" on
page 158.
E2112
Mem Spare
DIMM ##
The system BIOS has spared
the memory because it has
determined that the memory
had too many errors. "## &
##" represents the DIMM
pair implicated by the BIOS.
See "Troubleshooting
System Memory" on
page 158.
E2113
Mem Mirror
DIMM ## & ##
They system BIOS has
disabled memory mirroring
because it has determined
that one half of the mirror
has had too many errors.
"## & ##" represents the
DIMM pair implicated by
the BIOS.
See "Troubleshooting
System Memory" on
page 158.
E2118
Fatal NB Mem
CRC
One of the connections in
the
Fully Buffered DIMM
(
FBD) memory subsystem
link on the Northbound side
has failed.
See "Troubleshooting
System Memory" on
page 158.
E2119
Fatal SB Mem
CRC
One of the connections in
the FBD memory subsystem
link on the Southbound side
has failed.
See "Troubleshooting
System Memory" on
page 158.
I1910
Intrusion
System cover has been
removed.
Information only.
Table 1-6.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions
book.book Page 32 Monday, September 14, 2009 1:53 PM