8-2

ADS FlowShark Pulse O&M Manual

Quick Start Guide for Setting Parameters

Set the following parameters for a standard installation using the FlowShark Pulse
menu:

1. EXTRA > Units Select the units of measure for flow rate (mgd), velocity

(ft/s), depth/height (ft), and total (ft³) (units in brackets reflect the default
settings).

2. PAR > Measurement place > Channel profile Select the profile of the

pipe or channel.

3. PAR > Measurement place > Channel dimensions Enter the

dimensions of the channel or pipe.

4. EXTRA > Display Adjust the brightness and contrast for the display, if

necessary.

5. EXTRA > System time Adjust the time, if necessary.

Additional Settings

6. PAR > Measurement place > Name Enter the name of the measurement

location.

7. PAR > analog outputs > Function Enable analog output 1 (flow).

8. PAR > analog outputs > output span Select the output range (e.g., 4 –

20 mA).

9. PAR > analog outputs > measurement span Select the specific entity

measurement range (e.g., 0 – 20 mgd).

10. PAR > analog outputs > error mode Designate the default depth value

the analog output should report when a sensor error occurs.

11. PAR > Relay outputs > Function Enable relay 1 (select pos-total

impulse).

12. PAR > Relay outputs > Pulse parameter Set the impulse value (e.g.,

volume of flow after which an impulse is triggered) and duration.

When finished setting the parameters, exit the parameter settings and save the settings
by entering the following code number: 2718.