Language, Display, System time – ADS Environmental Services FlowShark Pulse QR 775004 A1 User Manual
Page 100: Totalizer

8-10 ADS FlowShark Pulse O&M Manual
Language
This option enables the user to select the language (German, English, French, Czech,
or Italian) in which readings will display.
Display
This feature allows the user to adjust the display settings regarding contrast and
brightness. Use
and
to decrease settings; use
and
to increase settings.
and
modify settings at 5 percent increments;
and
modify settings at1
percent increments.
System Time
To perform various control and memory functions, the unit includes an internal
system clock for saving dates corresponding to years, weekdays, and week numbers.
The user can modify clock date and time.
First, select the Info menu option:
Figure 8-14 System time submenu
The unit displays the system time after confirming the settings:
Figure 8-15 System time (date, calendar week, time)
This menu option is for display purposes only. Therefore, the user cannot adjust the
system time through this option. Perform these modifications through the Date and
Time menu options.
The corresponding week number will be set automatically once the date has been set.
Totalizer
This menu option allows the user to manually set the totalizer displayed on the main
screen. This function typically would be performed when replacing a transmitter to
ensure the same value displays following replacement.
After setting the new value, click on the Enter key twice consecutively to confirm
and then enter the code number 2718 to accept the new value. The unit offers the
user two attempts to enter the correct code.