Operator’s manual – Great Plains DICKEY-john AI-120 12-inch Virtual Terminal User Manual
Page 91

OPERATOR’S MANUAL
AI-120 Virtual Terminal
11001-1606B-201310
AUTO SECTION CONTROL SETUP / 83
SECTION CONTROL SHUTOFF BY CHANNEL
Section control shutoff by channel is an optional feature to shutoff rows
when there are no output or switch modules connected to the system. Rows
are shutoff based on the number of rows assigned to a channel when
approaching a previously applied area.
To enable Section Control by Channel:
1. At the Setup menu, verify that ‘Auto Section Control’ is enabled
(System, Features, Implement).
2. Verify that either ‘Section Control Only’ or ‘Section Control and Rate
Control’ is selected at the ECU Setup menu (Implement, ECU,
Implement Control)
– Section Control by Channel is disabled by selecting Rate Control
only.
3. At the Main Menu, open the Auto Section Control window and select to
turn off channels by:
– Avoiding gaps--turns off the channel when the last row assigned to
the channel crosses the previously planted area causing overlap.
– Avoiding overlaps--turns off the channel when the first row
assigned to the channel crosses the previously planted area
causing a gap.