3 import protocol - properties, Import protocol - properties – Metrohm tiBase 1.0 Manual User Manual
Page 114

3.5 Subwindow Import protocol
■■■■■■■■■■■■■■■■■■■■■■
106
■■■■■■■■
tiBase 1.0
Details
Detailed information on the log entry.
Functions
The menu Edit beneath the table contains the following menu items:
Delete all messages
Delete all messages in the window Import protocol.
Options...
Open the dialog window Properties Import protocol.
3.5.3
Import protocol - Properties
Dialog window: Configuration
▶ Import protocol ▶ [Edit] ▶ Options...
Filter options
Show information
on | off (Default value: off)
If this check box is activated, information on the import process is shown in
the table.
Show warnings
on | off (Default value: off)
If this check box is activated, warnings are shown in the table.
Show errors
on | off (Default value: off)
If this check box is activated, errors during the import are shown in the table.
Maximum number of log entries
In this field the maximum number of log entries to be listed in the table
Import protocol is entered.
If the number of entries exceeds the value entered, rolling recording takes
place. This means, that the oldest entry is deleted when a new log saying is
incoming.
Range
20 ... 1000
Default value
100
Note
If during a rolling recording an error or warning not remedied yet has
been deleted, the warning or error will be newly logged as soon as the
corresponding import process is started again.