Rockwell Automation SA500 Drive Configuration and Programming User Manual
Page 71
Configuring the UDC Module’s Registers
3-39
Motor Speed in RPM Register
217/1217
The Motor Speed in RPM register contains the speed of the motor in
revolutions per minute. A positive number in this register indicates a
forward direction; a negative number indicates a reverse direction.
Sug. Var. Name:
RPM%
Units:
RPM
Range:
N/A
Access:
Read only
Note that this register is not intended for closed loop control.
Position Error Register
218/1218
The Position Error register contains the error output value of the
position loop. An error value of 4095 equals one mechanical
revolution of the resolver.
Sug. Var. Name:
POS_ERR%
Units:
Counts
Range:
+/-4095
Access:
Read only
Speed Loop P+I Output Register.
219/1219
The Speed Loop P+I Output register contains the proportional and
integral torque output of the speed loop. A value of 4095 equals the
torque limit.
Sug. Var. Name:
SPI_OUT%%
Units:
Counts
Range:
+/-4095
Access:
Read only
Speed Loop Feedforward Output Register
220/1220
This register contains the feedforward output value of the PMI speed
loop. A value of 4095 equals the torque limit.
Sug. Var. Name:
WR2_COMP%
Units:
Counts
Range:
+/-4095
Access:
Read only
Slip RPM Register
221/1221
The Slip RPM register contains the slip value in RPM. This register is
used only when vector or vector speed loop enhanced regulation is
selected.
Sug. Var. Name:
SLP_RPM%
Units:
RPM
Range:
Motor dependent
Access:
Read only