Configuring the UDC Module’s Registers

3-39

Motor Speed in RPM Register

217/1217

The Motor Speed in RPM register contains the speed of the motor in
revolutions per minute. A positive number in this register indicates a
forward direction; a negative number indicates a reverse direction.

Sug. Var. Name:

RPM%

Units:

RPM

Range:

N/A

Access:

Read only

Note that this register is not intended for closed loop control.

Position Error Register

218/1218

The Position Error register contains the error output value of the
position loop. An error value of 4095 equals one mechanical
revolution of the resolver.

Sug. Var. Name:

POS_ERR%

Units:

Counts

Range:

+/-4095

Access:

Read only

Speed Loop P+I Output Register.

219/1219

The Speed Loop P+I Output register contains the proportional and
integral torque output of the speed loop. A value of 4095 equals the
torque limit.

Sug. Var. Name:

SPI_OUT%%

Units:

Counts

Range:

+/-4095

Access:

Read only

Speed Loop Feedforward Output Register

220/1220

This register contains the feedforward output value of the PMI speed
loop. A value of 4095 equals the torque limit.

Sug. Var. Name:

WR2_COMP%

Units:

Counts

Range:

+/-4095

Access:

Read only

Slip RPM Register

221/1221

The Slip RPM register contains the slip value in RPM. This register is
used only when vector or vector speed loop enhanced regulation is
selected.

Sug. Var. Name:

SLP_RPM%

Units:

RPM

Range:

Motor dependent

Access:

Read only