UDC Module Ports A/B CRC Error Count Register
82/1082
This register contains the number of messages with CRC errors
received by the UDC module on port A and port B.
Sug. Var. Name:
N/A
Units:
Counts
Range:
N/A
Access:
Read only
UDC Module Ports A/B Format Error Count Register
83/1083
This register contains the number of messages with format errors
received by the UDC module on port A and port B.
Sug. Var. Name:
N/A
Units:
Counts
Range:
N/A
Access:
Read only
PMI A/B Communication Status Register
84/1084
The PMI A/B Communication Status register contains bits which describe any errors or warnings reported by
PMI A or PMI B related to UDC/PMI communication. These bits are latched when set and will remain set
until a fault reset or warning reset is issued.
Invalid Receive Interrupt
Bit 0
The Invalid Receive Interrupt bit is set if the
interrupt generated by the Universal Serial
Controller (USC) is not properly marked.
Hex Value:
0001H
Sug. Var. Name:
N/A
Access:
Read only
UDC Error Code: N/A
LED:
N/A
No End of Frame Status Received
Bit 1
The No End of Frame Status Received bit is
set if the USC does not report an End of
Frame condition when the receive interrupt
is generated.
Hex Value:
0002H
Sug. Var. Name:
N/A
Access:
Read only
UDC Error Code: N/A
LED:
N/A
CRC/Framing Error
Bit 2
The CRC/Framing Error bit is set if the USC
reports a CRC or Framing error on the last
frame (message) received.
Hex Value:
0004H
Sug. Var. Name:
N/A
Access:
Read only
UDC Error Code: N/A
LED:
N/A