beautypg.com

Ontents – Rockwell Automation SA500 Drive Configuration and Programming User Manual

Page 3

background image

Table of Contents

I

C

ONTENTS

Chapter 1

Introduction

Chapter 2

Configuring the UDC Module, Regulator Type, and Parameters
2.1

Adding a UDC Module ..................................................................................... 2-1

2.2

Entering the Drive Parameters ........................................................................ 2-2

2.3

Using the Brushless Parameter Entry Screens ............................................... 2-5
2.3.1 Power Module Data Screen (Brushless) ............................................... 2-5
2.3.2 Motor Data Screen (Brushless) ............................................................. 2-6
2.3.3 Motor Data Screen (Brushless - Speed Loop Enhanced) ..................... 2-7
2.3.4 Feedback Data Screen (Brushless) ...................................................... 2-9
2.3.5 Feedback Data Screen (Brushless - Speed Loop Enhanced)............. 2-10

2.4

Using the Vector Parameter Entry Screens................................................... 2-12
2.4.1 Power Module Data Screen (Vector)................................................... 2-12
2.4.2 Motor Data Screen (Vector) ................................................................ 2-13
2.4.3 Motor Data Screen (Vector - Speed Loop Enhanced)......................... 2-15
2.4.4 Feedback Data Screen (Vector).......................................................... 2-17
2.4.5 Feedback Data Screen (Vector - Speed Loop Enhanced) .................. 2-19

2.5

Generating the Drive Parameter Files and Printing Drive Parameters .......... 2-21

Chapter 3

Configuring the UDC Module’s Registers
3.1

Register and Bit Reference Conventions Used in this Manual ........................ 3-2

3.2

Rail I/O Port Registers (Registers 0-23) .......................................................... 3-6

3.3

UDC/PMI Communication Status Registers (Registers 80-89/1080-1089) ..... 3-9

3.3

Command Registers (Registers 100-149/1100-1149) ................................... 3-17

3.4

Volatile Gain Registers (Registers 150-199/1150-1199) ............................... 3-23
3.4.1 Speed Loop Gain Variables ................................................................ 3-23
3.4.2 Position Loop Gain Variables .............................................................. 3-24

3.5

Feedback Registers (Registers 200-299/1200-1299).................................... 3-26

3.6

Application Registers (Registers 300-599, Every Scan)
(Registers 1300-1599, Every Nth Scan) ........................................................ 3-40

3.7

UDC Module Test I/O Registers (Registers 1000-1017) ............................... 3-43
3.7.1 UDC Module Test Switch Inputs Register (Register 1000) ................. 3-43
3.7.2 UDC Module Meter Port Setup Registers (Registers 1000-1017)....... 3-45

3.7.2.1 Resolution of Meter Port Data............................................... 3-46

3.8

Interrupt Status and Control Registers (Registers 2000-2047) ..................... 3-51

Chapter 4

Application Programming for DPS Drive Control
4.1

AutoMax Tasks ................................................................................................ 4-1

4.2

UDC Tasks ...................................................................................................... 4-1
4.2.1 Typical Structure of a UDC Task........................................................... 4-3
4.2.2 Local Tunable Variables........................................................................ 4-6

4.2.2.1 Calculating Local Tunable Values........................................... 4-7

4.2.3 UDC/PMI Task Communication ............................................................ 4-7

4.3

AutoMax Processor Task and UDC Task Coordination .................................. 4-9