Rockwell Automation SA500 Drive Configuration and Programming User Manual
Page 69

Configuring the UDC Module’s Registers
3-37
Interlock Register (Continued)
205/1205
Rising Edge Required
Bit 4
The Rising Edge Required bit is set if a
rising edge is required on any command bit
in register 100/1100.
Hex Value:
0010H
Sug. Var. Name:
IC_RISE@
Access:
Read only
UDC Error Code: N/A
LED:
N/A
This bit will be set if the application task has set the Fault Reset bit (register
100/1100, bit 8) but has not cleared and then re-set any command bits.
More Than One Drive Request
Bit 5
The More Than One Drive Request bit is set
if more than one operating mode is
requested at a time in register 100/1100
(bits 0 and 1).
Hex Value:
0020H
Sug. Var. Name:
IC_MORE@
Access:
Read only
UDC Error Code: N/A
LED:
N/A
MCR Did Not Close
Bit 7
The MCR Did Not Close bit is set if the
optional output contactor did not close when
commanded to do so.
Hex Value:
0080H
Sug. Var. Name:
IC_MCR@
Access:
Read only
UDC Error Code: N/A
LED:
N/A
Speed Feedback Register
206/1206
The Speed Feedback register contains the speed feedback data from
the PMI speed loop.
Sug. Var. Name:
SPD_FB%%
Units:
Counts
Range:
+/-4095
Access:
Read only
Torque Feedback Register
207/1207
The Torque Feedback register contains the torque setpoint feedback
data from the PMI speed loop.
Sug. Var. Name:
TRQ_FB%
Units:
Counts
Range:
+/-4095
Access:
Read only
Position Feedback Register
208/1208
The Position Feedback register contains the position feedback data
from the PMI position loop.
Sug. Var. Name:
POS_FB%
Units:
Counts
Range:
+/-32767
Access:
Read only