3-38

SA500 Drive Configuration and Programming

Position Loop Register

209/1209

The Position Loop register contains the velocity output value from the
PMI position loop.

This value can be used to indicate that the position loop is active.

Sug. Var. Name:

POS_REG_OUT

%

Units:

Counts

Range:

+/-4095

Access:

Read only

Current Feedback (Normalized) Register

211/1211

The Current Feedback (Normalized) register contains the measured
RMS motor current. The data is normalized so that 4095 counts is
equal to the current limit.

Sug. Var. Name:

I_FBN%

Units:

Counts

Range:

+/-4095

Access:

Read only

This value is used as the I_FDBK parameter in the THERMAL OVERLOAD control block used in DPS drives
to monitor the motor for thermal overload.

Speed Error Register

213/1213

The Speed Error register contains the error output value of the speed
loop, where 4095 equals the gear-in-speed. If this value exceeds the
user-selected value stored in the Maximum Velocity Error register
(156/1156) a drive fault (register 202/1202, bit 5) will be generated.

Sug. Var. Name:

SPD_ERR%

Units:

Counts

Range:

+/- 4095

Access:

Read only

User Analog Input Register

214/1214

The User Analog Input register contains the digitized value of a
user-selected analog input.

Sug. Var. Name:

USER_AIN%%

Units:

Counts (volts)

Range:

-2048 (-10V) to

+2047 (+10V)

Access:

Read only

Resolver Scan Position Register

215/1215

The Resolver Scan Position register contains the digitized value of
the resolver position data.

Sug. V ar. Name:

RES_SCN_POS

%

Units:

Counts

Range:

-32768 to +32767

Access:

Read only

Resolver Strobe Position Register

216/1216

The Resolver Strobe Position register contains the electrical position
of the resolver at the time a strobe signal is detected.

Sug. Var. Name:

RES_STR_POS

%

Units:

Counts

Range:

-32768 to +32767

Access:

Read only