G
•
Features supported in different versions of FactoryTalk View
G-5
•
•
•
• •
Use variable minimum/maximum
property assigned to Numeric Input
Cursor Point or Numeric Input
Enable object
In the Numeric tab of the object’s Properties dialog box,
clear the Use variable minimum/maximum property.
Caption on Keypad property
assigned to Numeric Input Cursor
Point object
In the Numeric tab of the object’s Properties dialog box,
set the Caption on keypad/scratchpad property to blank.
Minimum or Maximum connections
assigned for Numeric Input Cursor
Point or Numeric Input Enable
object
In the Connections tab of the object’s Properties dialog
box, delete the tag or expression assigned to the Minimum
or Maximum connection.
Use variable ramp or Use variable
limit property set for the Ramp
button object
In the General tab of the object’s Properties dialog box,
clear the Use variable lower/upper limit and Use variable
ramp value properties.
Ramp or Limit connection set for the
Ramp button object
In the Connections tab of the object’s Properties dialog
box, delete the tag or expression assigned to the Ramp or
Limit connection.
The application is designated as a
Compact Machine Edition
application in Project Settings
In the General tab of the Project Settings editor, clear the
Compact Machine Edition application check box.
To remove or replace this feature
Do this