Rockwell Automation 1746-HSRV SLC Servo Control Module User Manual User Manual
Page 176

Publication 1746-6.1.2 - July 2000
Input/Output Quick Reference A-3
1
s = Slot number for the SLC Servo Module
01 – Homing to a
Marker, (10=0, 9=1),
Specifies that the axis is homed by moving to a
marker. The two parameters,
Final Move to Which
Marker? and Final Move to Marker?, specify which marker
to move to and whether the final move to the marker is
required or not.
10 – Homing to a Limit
Switch (10=1, 9=0),
Specifies that the axis is homed only using a limit
switch and markers are not used for homing. This
can result in a final home position that can be
inaccurate as markers are not used for homing.
11 – Homing to a Limit
Switch and Marker
(10=1, 9=1)
Specifies that the axis is homed using both the limit
switch and marker. When the limit switch is found
and a move is made to go off the limit switch, the
home sequence is identical to home to marker. As a
result, the two parameters,
Final Move to Which
Marker? and Final Move to Marker?, specify which marker
to move to and whether the final move to the marker is
required or not.
Final Move to Which
Marker?
(Homing)
M0:s.0/11
Marker Nearest Start
Position (0) / 1 Rev,
then Nearest Marker
(1)
Marker
Nearest
Start
Position
Marker Nearest Start Position (0) configures the axis
to move to the nearest marker from the start position
of the final move to the marker of the homing
sequence. Move to one (1) revolution of the
feedback device in the direction and at the speed
specified by the Home Axis command, then stop. The
axis then moves to the nearest marker.
Final Move to Marker?
(Homing)
M0:s.0/12
Yes (1) / No (0)
Yes
If set, the axis performs the final move to the marker
specified by
Final Move to Which Marker?. Otherwise,
the axis does not perform the final move to the marker
specified by
Final Move to Which Marker?, but instead
assigns the current position of the axis to the configured
Home Position ± the distance to the nearest marker. Refer
to
Homing to a Limit Switch in this manual for alternate
usage.
Enable Incremental
Position Command
(System)
M0:s.0/13
Yes (1) / No (0)
No
If the incremental position command is enabled, the
SLC Servo Module does not execute blend profile
moves and the appropriate error messages are
generated when a profile move is commanded.
Blend Move Profile
(System)
M0:s.0/14
Yes (1) / No (0)
No
Mode Flag
(System)
M0:s.0/15
Configure (1) /
Command (0)
Command
Parameter Name
(Parameter Group)
Destination M
1
FileLocation
Range
Default
Additional Information