Rockwell Automation 1746-HSRV SLC Servo Control Module User Manual User Manual
Page 170

Publication 1746-6.1.2 - July 2000
Troubleshooting 10-11
1040
Speed of move off the limit switch is out of range.
If the speed specified is less than one feedback count per
coarse iteration time or greater than the maximum speed
configured, change the parameter specification.
1041
Speed of move to marker is out of range.
If the speed specified is less than one feedback count per
coarse iteration time or greater than the maximum speed
configured, change the parameter specification.
1042
Acceleration time specified is out of range.
If the acceleration time specified is less than coarse
iteration time, change the parameter specification.
1043
Home position specified is out of range.
If the home position specified is greater than the positive
overtravel limit or less than the negative overtravel limit,
change the parameter specification.
1044
Positive travel limit specified is less than the negative
travel limit.
Change the parameter specification.
1045
Negative travel limit specified is greater than the
positive travel limit.
Change the parameter specification.
1046
Rollover position specified is not equal to zero when
overtravels are used.
Set the rollover position to zero.
1047
Home position is outside the rollover range.
Make home position less than the rollover position.
1048
Output voltage at positive max speed is out of range.
Range is 0 to 10.0 Volts.
1049
Output voltage at negative max speed is out of range.
Range is 0 to –10.0 Volts.
1050
The velocity feedforward constant is out of range.
Range is 0 to 1.0.
1051
The acceleration feedforward constant is out of range.
Range is 0 to 1.0.
1052
Reversal error compensation is too big.
Reduce the parameter value.
1053
The maximum speed specified is too small.
If the speed specified is less than one internal unit per
iteration, change the parameter specification.
1054
The maximum acceleration specified is too big.
If the acceleration specified requires system to reach
maximum speed in less than one coarse iteration, change
the parameter specification.
1055
The positive DAC scaling is too big.
Change maximum speed or volts at maximum speed.
1056
The positive DAC scaling is too small.
Change maximum speed or volts at maximum speed.
1057
The negative DAC scaling is too big.
Change maximum speed or volts at maximum speed.
1058
The negative DAC scaling is too small.
Change maximum speed or volts at maximum speed.
1059
The home position specified is out of range.
If the home position cannot be converted to internal
resolution units, change the parameter.
1060
The home calibration specified is out of range.
If the home calibration cannot be converted to internal
resolution units, change the parameter.
1061
The rollover position specified is out of range.
If the rollover position cannot be converted to internal
resolution units, change the parameter.
1062
The maximum gain specified is out of range.
If the maximum gain cannot be converted to internal
resolution units, increase the value.
Minor Fault
Message No.
Potential Cause
Possible Resolution